Intelligent Data Centres Issue 09 | Page 63

UNCOVERING THE LAYERS Power Supply (UPS), switchgear, transformers and Cold Aisle containment. Eaton looked at the load that Amdocs predicted it would run in its data centre and proposed using its 93PM UPS range – one of the most efficient on the market and quite a simple, straight-forward solution to the Amdocs UPS specification. Ronnen Perry, Global Technical Manager and Regional Facility Manager at Amdocs the two companies put forward a solution using Eaton switchgear and UPS back- up. At the same time, Carter Sullivan coordinated the fit out of the state-of-the- art air conditioning system throughout the data centre. Solution Eaton and Carter Sullivan implemented a complete power security solution based on the design provided by the Amdocs team and built around Eaton’s Uninterruptable www.intelligentdatacentres.com The 120kW unit is completely aligned with the requirement and the battery system is sized accordingly. The 93PM UPS guarantees power supply for a defined period to critical loads in the event of a power failure. The unit also protects critical loads by filtering out power fluctuations, such as voltage spikes, and providing continuously high-quality power. The design of the 93PM is based on online double conversion technology, which is widely recognised as giving the best possible protection because it guarantees a clean and reliable power supply regardless of the quality of the grid. Energy loss with the 93PM is minimal, compared to traditional double conversion UPS devices, and it can achieve an efficiency rating of 96.7%. After the initial install of the power quality items, attention turned to how the team could further increase energy efficiency within the data centre. Two rows comprising 30 42U server cabinets sat in an open area and after conducting a survey Eaton and Carter Sullivan designed and installed the cold aisle containment, which provides more effective airflow management. This was a completely bespoke design and comprised a set of aisle doors with roof panels. Mark Anderson, Managing Director at Carter Sullivan, said: “Collaboration drove the success of this project. There was a great working relationship between all the companies involved, which meant that the tight timing of the build could be achieved and we could give Amdocs a data centre solution that will enable business growth and improve efficiency.” He added: “We worked closely with Eaton to deliver a solution based on their xEnergy switchgear, Uninterruptable Power Supply and electrical panel components – all of which were integral Issue 09 63